INTRODUCTION

A contestable works program exists under the NSW Electricity Supply Act 1995. This provides electricity customers in NSW with the right to choose suitably qualified and accredited persons to connect their premises to the Network Operator’s distribution network, arrange for the supply of more electricity from the distribution network than they are currently consuming, or to extend the distribution network to reach their premises.

To ensure that the electrical distribution network and connection to the distribution network remains reliable and safe, only Accredited Service Providers (ASPs) operating under the ASP scheme administered by NSW Trade & Investment, may perform this work.

Employees and sub-contractors of ASPs must be suitably qualified and registered with the ASP scheme before seeking authorisation from the local Network Operator to work on or near the electricity network.

ASP LEVELS

The ASP Scheme accredits different types (levels) of work.

LEVEL 1 ACCREDITATION

allows for both overhead and underground construction work on distribution networks which are located adjacent to roadway. Level 1 service providers may be accredited for the following work categories:

  • overhead lines
  • underground lines.

LEVEL 2 ACCREDITATION

allows for construction of service lines between the distribution system and the point of connection to the premises and for the installation and energisation of metering services. Level 2 service providers may be accredited for the following work categories:

  • disconnection and reconnection
  • underground service lines
  • overhead service lines
  • metering and energising new installations
  • installing contestable market metering

LEVEL 3 ACCREDITATION

allows for the design of distribution networks. Service providers may be accredited for the following work categories:

  • overhead lines
  • underground lines.

level 2 qualifications

The services that can be undertaken by a Level 2 ASP are as follows (but not limited to):

Class 2A
(previously known as Category 1) – Disconnect and reconnect.

  • Disconnection and reconnection of service lines at the connection point – but only work at the connection point that does not involve accessing network operator assets and no mechanical changes to network assets are required.

Class 2B
(previously known as Category 2) – Work on underground service conductors. For example:

  • remove and replace a local electricity distributor security seal in accordance with local electricity distributor procedures;
  • installation and connection of underground service lines in accordance with the NSW Service & Installation Rules;
  • relocate/upgrade an existing underground service line and restore supply on completion;
  • disconnection and reconnection of underground service lines at the point of common coupling and the connection point; and
  • replacement of service protection device and meter protection device fuse(s), service active and neutral links

Class 2C
(previously known as Category 3) – Work on overhead service conductors. For example:

  • remove and replace a local electricity distributor security seal in accordance with local electricity distributor procedures;
  • installation and connection of overhead service lines in accordance with the Service & Installation Rules of NSW;
  • relocate/upgrade an existing overhead service line and restore supply on completion;
  • disconnection and reconnection of overhead service lines at the point of common coupling and the connection point; and
  • replacement of service protection device and meter protection device fuse(s), service active and neutral links.

Class 2D
(previously known as Category 4) – Installing metering for meter types 5 to 6 and other Network Operator service equipment:

  • remove and replace a local electricity distributor security seal in accordance with local electricity distributor procedures;
  • installation and removal of whole current metering equipment in accordance with the local distributor’s published standards; and
  • disconnection and reconnection of the installation at the connection point; and
  • energising new installations.

An ASP may only remove or install meters of types 1 to 4 if the ASP is also accredited as a meter provider with the Australian Energy Market Operator (AEMO) or the ASP is undertaking this work as a sub-contractor to another company which is properly accredited by AEMO for this purpose.

Class 2X
Non-electrically qualified. This class allows non-electrically qualified personnel to be registered with the ASP Scheme in accordance with the Scheme Rules. It also allows application to be made to a distributor for authorisations not covered in the Scheme Rules, where the requirements for those authorisations are set by the Distributors. Examples of specific authorisations that may be required by a distributor include:

  • electrical trade related works performed by electrical trades apprentices covered by a training contract that may be required to work on or near the network under direct and constant supervision of an appropriately authorised person,
  • work performed by persons engaged by a telecommunications network operator on telecommunications assets attached to electricity network operator assets,
  • trades assistant work such as safety observer, rescue assistant and plant operator.

Level 2 Training and Assessment requirements


Level 2 ASP Qualification and training requirements
Classes of Contestable Services
(type of work)
ASP Scheme Qualification Criterion for Level 2 ASPs
Training organisations must be registered with Australian Skills Quality Authority or their state training authority and must have the relevant qualification and unit of competency on their scope of registration to deliver training and/or assessment.
Core Qualifications (refer Note 1) Additional Mandatory Competency Units (refer Note 2)
Class 2A -
Disconnect and
reconnect at
connection point
Meet requirements for class 2B or 2C
OR
Currently registered for Disconnect / reconnect
(former Level 2 Category 1)
UETTDREL16A - Working safely near live electrical apparatus
AND
UETTDRRF11A - Testing of connections to low voltage electricity networks
Class 2B -
Underground Services
(previous Category 2)
UET30811 - Certificate III in Electro-technology Electrician (or equivalent)
OR
UET30812 - Certificate III in ESI - Power Systems - Distribution Cable Jointing
UETTDRIS55A - Install and maintain low voltage underground services AND
UETTDRRF11A - Testing of connections to low voltage electricity networks,
Class 2C -
Overhead Services
(previous Category 3)
UET30811 - Certificate III in Electrotechnology
Electrician (or equivalent)
OR
UET30612 - Certificate III in ESI - Power Systems -
Distribution Overehad
UETTDRIS56A - Install and maintain low voltage overhead services AND
UETTDRRF11A - Testing of connections to low voltage electricity networks,
Class 2D -
Metering & Energised
Installations - including
disconnect and reconnect
(previous Category 4)
UET30811 - Certificate III in Electro-technology
Electrician (or equivalent)
UETTDREL16A - Working safely near live electrical apparatus
AND
UEENEEK142A - Apply enviromentally and suistainable energy procedures in the energy sector
AND either
  1. UETTDRIS60A - Install and replace power system meters and associated equipment, or,
  2. UEENEEG171A - install, setup and commission interval metering
AND
UETTDRRF11A - Testing of connections to low voltage electricity networks
Note 1:
Upon verification, those holding an equivalent qualification to
  • UET30612 and/or UET30812 documented in the UET12 Training Package and all corresponding units of competency that proceed back to and are inclusive of UTT30101 and/or UTT30301 documented in the UTT98 Training Package will also meet the qualification requirements noted in this Level 1 table; or
  • UEE30811 documented in the UEE11 Training Package and all corresponding units of competency that proceed back to and are inclusive of UTE31199 documented in the UTE99 Training Package will also meet the qualification requirements noted in this Level 1 table.
Note 2:
Registered Training Organisations (RTO's) must ensure that any/all prerequisite units of competency (as specified within each of the relevant competency standards) have been achieved prior to awarding any of the units of competency specified within "Additional Mandatory Competency Units" column of Level 1 table.
Details are to be submitted in the qualifications section of the Level 2 ASP Application Form

Transitional arrangements

(a) All existing Level 2 ASPs and personnel registered before December 31st 2015 will continue to have their training recognised as before and to hold the relevant categories of registration.
(b) From December 31st 2015, any evidence of training which complies with the table above will be accepted as part of an application for registration.
(c) Until 31 December 2015, the scheme administrator will accept training certificates issued under the previous method used to train Level 2 ASPs as part of an application for registration. This will allow RTOs to transition to the new training requirements and allow individuals to complete their training and submit an application in a timely manner.
(d) From 1 January 2016, only training which complies with Appendix B will be accepted as part of an application for registration unless an individual has been registered previously as per (a) above.

CATEGORY 2 UNDERGROUND
TRAINING AND ASSESSMENT

UETTDRIS55A
Install and maintain low voltage underground services

Unit Descriptor: This Competency Standard Unit covers the installation, maintenance and connection of low voltage underground service lines and associated equipment (between the connection point and the point of supply - customers’ premises). Maintenance includes the repair and replacement of service cables, service fuses and the replacement and repair of service hardware, the identification and rectification of faults. It also covers insulation, voltage, polarity testing and phase rotation.

Learning Outcomes: At the completion of this Unit of Competency, you should be able to:
1. Prepare for the installation and maintenance of LV underground services and associated equipment
2. Carry out installation and maintenance of LV underground services and associated equipment
3. Complete the installation and maintenance of LV underground services and associated equipment.

Prerequisite Unit(s) Competencies: Granting of competency in this unit shall be made only after competencies in the Common Unit Group have been completed plus all the competencies in one (1) of the identified Pathway Unit Group(s): Transmission Overhead, Distribution Overhead, Rail Traction, Distribution Cable Jointing, Electrotechnology Electrician (Refer to Pathway over).

Scheduling: The delivery duration is approximately 2 days or as required.

UETTDRIS55A [Pathway]

plus
Common Unit Group
Unit Code Unit Title
UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace
UEENEEE102A Fabricate, assemble and dismantle utilities industry components
UEENEEE104A Solve problems in d.c. Circuits
UEENEEE105A Fix and secure electrotechnology equipment
UEENEEE107A Use drawings, diagrams, schedules, standards, codes and specifications
UEENEEG101A Solve problems in electromagnetic devices and related circuits
UEENEEG102A Solve problems in low voltage a.c. Circuits
UETTDREL16A Working safely near live electrical apparatus
or
Transmission Overhead Pathway Group
Unit Code Unit Title
UETTDREL11A Apply sustainable energy and environmental procedures
UETTDREL12A Operate plant and equipment near live electrical conductors and apparatus
UETTDRIS54A Install and maintain poles, structures, overhead conductors and cables
UETTDRTP26A Install transmission structures and associated hardware
UETTDRTP27A Maintain transmission structures and associated hardware
UETTDRTP29A Install and maintain transmission overhead conductors and cables
or
Distribution Overhead Pathway Group
Unit Code Unit Title
UETTDRDP12A Maintain overhead energised low voltage conductors and cables
UETTDREL11A Apply sustainable energy and environmental procedures
UETTDREL12A Operate plant and equipment near live electrical conductors and apparatus
UETTDRIS41A Install network infrastructure electrical equipment
UETTDRIS42A Maintain network infrastructure electrical equipment
UETTDRIS52A Install and maintain poles, structures and associated hardware
UETTDRIS54A Install and maintain poles, structures, overhead conductors and cables
UETTDRIS56A Install and maintain low voltage overhead services
or
Rail Traction Pathway Group
Unit Code Unit Title
UETTDREL11A Apply sustainable energy and environmental procedures
UETTDREL12A Operate plant and equipment near live electrical conductors and apparatus
UETTDRIS52A Install and maintain poles, structures and associated hardware
UETTDRIS54A Install and maintain poles, structures, overhead conductors and cables
UETTDRRT21A Install traction overhead wiring systems
UETTDRRT22A Maintain traction overhead wiring systems
UETTDRRT23A Install rail traction bonds
UETTDRRT27A Install overhead traction components and equipment
UETTDRRT28A Maintain overhead traction components and equipment
or
Distribution Cable Jointing Pathway Group
Unit Code Unit Title
UETTDRCJ21A Lay ESI electrical cables
UETTDRCJ26A Install and maintain de-energised low voltage underground polymeric cables.
UETTDRCJ27A Install and maintain de-energised high voltage underground polymeric cables.
UETTDREL11A Apply sustainable energy and environmental procedures
UETTDREL12A Operate plant and equipment near live electrical conductors and apparatus
Electrotechnology Electrician Pathway Group
Unit Code Unit Title
UEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology work
UEENEEG006A Solve problems in single and three phase low voltage machines
UEENEEG033A Solve problems in single and three phase electrical apparatus and circuits
UEENEEG063A Arrange circuits, control and protection for general electrical installations
UEENEEG106A Terminate cables, cords and accessories for low voltage circuits
UEENEEG108A Trouble-shoot and repair faults in low voltage electrical apparatus and circuits
UEENEEG109A Develop and connect electrical control circuits
UEENEEK142A Apply environmentally and sustainable energy procedures in the energy sector
UETTDRIS67A Solve problems in energy supply network equipment
 
UETTDRIS55A
Install and Maintain Low
Voltage Underground Services

CATEGORY 3 OVERHEAD
TRAINING AND ASSESSMENT

UETTDRIS56A
Install and maintain low voltage overhead services

This Competency Standard Unit covers the installation, maintenance and connection of low voltage overhead service lines and associated equipment (between the connection point and the point of supply - customers’ premises). Maintenance includes the repair and replacement of service cables, service fuses and the replacement and repair of service hardware, the identification and rectification of faults. It also covers insulation, voltage, polarity testing and phase rotation.

Learning Outcomes: At the completion of this Unit of Competency, you should be able to:
1. Prepare for the installation and maintenance of LV overhead services and associated equipment
2. Carry out installation and maintenance of LV overhead services and associated equipment
3. Complete the installation and maintenance of LV overhead services and associated equipment

Prerequisite Unit(s) Competencies: Granting of competency in this unit shall be made only after competency in the following unit(s) has/have been confirmed. Where pre-requisite pathways have been identified. All competencies in the Common Unit Group must be have been completed plus all the competencies in one (1) of the identified Pathway Unit Group(s): Transmission Overhead, Distribution Overhead, Rail Traction, Distribution Cable Jointing, Electrotechnology Electrician.

Scheduling: The delivery duration is approximately 4 days or as required.

UETTDRIS56A [Pathway]

plus
Common Unit Group
Unit Code Unit Title
UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace
UEENEEE102A Fabricate, assemble and dismantle utilities industry components
UEENEEE104A Solve problems in d.c. Circuits
UEENEEE105A Fix and secure electrotechnology equipment
UEENEEE107A Use drawings, diagrams, schedules, standards, codes and specifications
UEENEEG101A Solve problems in electromagnetic devices and related circuits
UEENEEG102A Solve problems in low voltage a.c. Circuits
UETTDREL16A Working safely near live electrical apparatus
or
Transmission Overhead Pathway Group
Unit Code Unit Title
UETTDREL11A Apply sustainable energy and environmental procedures
UETTDREL12A Operate plant and equipment near live electrical conductors and apparatus
UETTDRIS54A Install and maintain poles, structures, overhead conductors and cables
UETTDRTP26A Install transmission structures and associated hardware
UETTDRTP27A Maintain transmission structures and associated hardware
UETTDRTP29A Install and maintain transmission overhead conductors and cables
or
Distribution Overhead Pathway Group
Unit Code Unit Title
UETTDRDP12A Maintain overhead energised low voltage conductors and cables
UETTDREL11A Apply sustainable energy and environmental procedures
UETTDREL12A Operate plant and equipment near live electrical conductors and apparatus
UETTDRIS52A Install and maintain poles, structures and associated hardware
UETTDRIS54A Install and maintain poles, structures, overhead conductors and cables
or
Rail Traction Pathway Group
Unit Code Unit Title
UETTDREL11A Apply sustainable energy and environmental procedures
UETTDREL12A Operate plant and equipment near live electrical conductors and apparatus
UETTDRIS52A Install and maintain poles, structures and associated hardware
UETTDRIS54A Install and maintain poles, structures, overhead conductors and cables
UETTDRRT21A Install traction overhead wiring systems
UETTDRRT22A Maintain traction overhead wiring systems
UETTDRRT23A Install rail traction bonds
UETTDRRT27A Install overhead traction components and equipment
UETTDRRT28A Maintain overhead traction components and equipment
or
Distribution Cable Jointing Pathway Group
Unit Code Unit Title
UETTDRCJ21A Lay ESI electrical cables
UETTDRCJ26A Install and maintain de-energised low voltage underground polymeric cables.
UETTDRCJ27A Install and maintain de-energised high voltage underground polymeric cables.
UETTDREL11A Apply sustainable energy and environmental procedures
UETTDREL12A Operate plant and equipment near live electrical conductors and apparatus
UETTDRIS41A Install network infrastructure electrical equipment
UETTDRIS42A Maintain network infrastructure electrical equipment
UETTDRIS55A Install and maintain low voltage underground services
Electrotechnology Electrician Pathway Group
Unit Code Unit Title
UEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology work
UEENEEG006A Solve problems in single and three phase low voltage machines
UEENEEG033A Solve problems in single and three phase electrical apparatus and circuits
UEENEEG063A Arrange circuits, control and protection for general electrical installations
UEENEEG106A Terminate cables, cords and accessories for low voltage circuits
UEENEEG108A Trouble-shoot and repair faults in low voltage electrical apparatus and circuits
UEENEEG109A Develop and connect electrical control circuits
UEENEEK142A Apply environmentally and sustainable energy procedures in the energy sector
UETTDRIS67A Solve problems in energy supply network equipment
 
UETTDRIS56A
Install and maintain
low voltage overhead services

CATEGORY 4 METERING &
ENERGISING INSTALLATIONS
TRAINING AND ASSESSMENT

UETTDRIS60A
Install and replace power system energy meters and associated equipment

This Competency Standard Unit covers the installation and replacement of whole current energy meters and associated equipment, where replacement may include the identification of faults in accordance with established procedures and return to service. It includes the requirements to ascertain if normal functions of the meters and associated equipment are in accordance with established procedures.

Learning Outcomes: At the completion of this Unit of Competency, you should be able to:
1. Prepare for the installation and replacement of energy meters and associated equipment
2. Carry out the installation and replacement of energy meters and associated equipment
3. Complete the installation and replacement of energy meters and associated equipment

Prerequisite Unit(s) Competencies: Granting of competency in this unit shall be made only after competency in the following unit(s) has/have been confirmed. Where pre-requisite pathways have been identified. All competencies in the Common Unit Group must be have been completed plus all the competencies in one (1) of the identified Pathway Unit Group(s): Distribution Overhead, Distribution Cable Jointing, Electrotechnology Electrician

Scheduling: The duration of this unit of competency is approximately 4 days or as required.

UETTDRIS60A [Pathway]

plus
Common Unit Group
Unit Code Unit Title
UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace
UEENEEE102A Fabricate, assemble and dismantle utilities industry components
UEENEEE104A Solve problems in d.c. Circuits
UEENEEE105A Fix and secure electrotechnology equipment
UEENEEE107A Use drawings, diagrams, schedules, standards, codes and specifications
UEENEEG101A Solve problems in electromagnetic devices and related circuits
UEENEEG102A Solve problems in low voltage a.c. Circuits
UETTDREL16A Working safely near live electrical apparatus
or
Distribution Overhead Pathway Group
Unit Code Unit Title
UETTDRDP12A Maintain overhead energised low voltage conductors and cables
UETTDREL11A Apply sustainable energy and environmental procedures
UETTDREL12A Operate plant and equipment near live electrical conductors and apparatus
UETTDRIS41A Install network infrastructure electrical equipment
UETTDRIS42A Maintain network infrastructure electrical equipment
UETTDRIS52A Install and maintain poles, structures and associated hardware
UETTDRIS54A Install and maintain poles, structures, overhead conductors and cables
UETTDRIS56A Install and maintain low voltage overhead services
or
Distribution Cable Jointing Pathway Group
Unit Code Unit Title
UETTDRCJ21A Lay ESI electrical cables
UETTDRCJ26A Install and maintain de-energised low voltage underground polymeric cables.
UETTDRCJ27A Install and maintain de-energised high voltage underground polymeric cables.
UETTDREL11A Apply sustainable energy and environmental procedures
UETTDREL12A Operate plant and equipment near live electrical conductors and apparatus
UETTDRIS41A Install network infrastructure electrical equipment
UETTDRIS42A Maintain network infrastructure electrical equipment
UETTDRIS55A Install and maintain low voltage underground services
Electrotechnology Electrician Pathway Group
Unit Code Unit Title
UEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology work
UEENEEG006A Solve problems in single and three phase low voltage machines
UEENEEG033A Solve problems in single and three phase electrical apparatus and circuits
UEENEEG063A Arrange circuits, control and protection for general electrical installations
UEENEEG103A Install low voltage wiring and accessories
UEENEEG104A Install appliances, switchgear and associated accessories for low voltage electrical installations
UEENEEG106A Terminate cables, cords and accessories for low voltage circuits
UEENEEG107A Select wiring systems and cables for low voltage general electrical installations
UEENEEG108A Trouble-shoot and repair faults in low voltage electrical apparatus and circuits
UEENEEG109A Develop and connect electrical control circuits
UEENEEK142A Apply environmentally and sustainable energy procedures in the energy sector
 
UETTDRIS60A
Install and replace power system
energy meters and associated
equipment

Electrotechnology (Electrician’s pathway) Recognition

RTOs are obligated to recognise training and assessing that you have already undertaken, so you don’t need to undertake it again.
* UEENEEG105A Extract states that ‘Those holding an ‘Unrestricted Electrician’s Licence’ or equivalent issued in an Australian State or Territory meet the requirements of this unit and its pre-requisite requirements. A ‘licensed electrician’ applying for an ‘electrical contractors licence’ may be required to undertake this unit to demonstrate their currency with verification of compliance requirements. In this case they are deemed to have met the pre-requisites for this unit provided that they hold a current ‘electricians licence’ or its equivalent issued in an Australian State of Territory and have recently been in permanent employment as a licensed electrician sufficient to evidence current knowledge of applicable standards and regulations’.
Note: Electrician’s must still be subject to the recognition process for this to occur.

  Electrotechnology Electrician Pathway Group
Unit Code Unit Title
UEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology work
UEENEEG006A Solve problems in single and three phase low voltage machines
UEENEEG033A Solve problems in single and three phase electrical apparatur and circuits
UEENEEG063A Arrange circuits, control and protection for general electrical installations
UEENEEG106A Terminate cables, cords and accessories for low voltage circuits
UEENEEG108A Trouble-shoot and repair faults in low voltage electrical apparatus and circuits
UEENEEG109A Develop and connect electrical control circuits
UEENEEK142A Apply enviromentally and sustainable energy procedures in the energy sector
UETTDRIS67A Solve problems in energy supply network equipment
  Common Unit Group
Unit Code Unit Title
UEENEEE101A Apply Ocupational Health and Safety regulations, codes and practices in the workplace
UEENEEE102A Fabricate, assemble and dismantle utilities industry cmponents
UEENEEE104A Solve problems in d.c. Circuits
UEENEEE105A Fix and secure electrotechnology equipment
UEENEEE107A Use drawings, diagrams, schedules, standards, codes and specifications
UEENEEG101A Solve problems in electromagnetic devices and related circuits
UEENEEG102A Solve problems in low voltage a.c. Circuits
UETTDREL16A Working safely near live electrical apparatus
ACCREDITATION AUTHORISATION

To become accredited an applicant must apply in writing, using the
approved application form along with:
(a) the completed application form;
(b) evidence of the required competencies;
(c) the completed form for the registration of persons who will be
seeking to be authorised by the electricity distributor/s to undertake
contestable services;
(d) evidence of meeting the insurance requirements; and
(e) the application fee


Manager, Accreditation Services
Division of Resources and Energy
Level 12, 10 Valentine Ave
PARRAMATTA NSW 2051
Phone: 02 9842 8636
Email: asp.scheme@trade.nsw.gov.au

Following registration, an ASP must seek to have those personnel authorised by the local electricity distributor. Only personnel who are currently registered with the Scheme can be authorised.

The local electricity distributor is responsible for determining who is
authorised to work on or near the distribution network. The electricity distributor/s will require registered personnel to undertake training in relevant safety and operating procedures and be familiar with and show they can comply with their respective safety management systems, electrical safety rules and other relevant policies.

The 3 NSW Local Electricity Distributors are detailed below:



Statutory Training also required

Everybody who works on or near the Electricity Supply Network must be deemed competent in the tasks they are to perform; and trained and assessed yearly in the appropriate escape, release and rescue procedures for those tasks.

ASP Annual Refresher Training

Level 1 ASPs Level 2 ASPs Level 3
ASPs
Civil
Unit of Competency Cable
Worker
Pole
Worker
Substation
Electrical
Worker
Distribution
Substation
Electrical
Worker
Tower
Worker
Cat I&IV
ASP
Cat II ASP Cat III ASP Level 3
Designers
Crane and
Plant Operators
and Observers
In addition to workers above, their apprentices, trades assistants and persons working in
attendance must also do the same rescue. However, none of these workers are eligible to
undertake UETTDRRF11A
  • *
  • for cable jointing work on UGOHs
    on poles > 2m above ground level;
    and from EWPs
  • +
  • for live cable jointing work
    in a trench environment

Notes:

  • 1.
  • Cable Jointer / Cable Jointing and
    terminating in a trench environment
    and cable work above ground.
  • 2.
  • Electrical Fitter / Mechanic / Tester /
    Protection and Control work in a station
    environment.
  • 3.
  • Electrical Fitter / Mechanic / Tester /
    Protection and Control work outside a
    station environment at ground level.
  • 4.
  • Line Work on distribution
    or transmission poles.
  • 5.
  • Line Work on distribution
    or transmission towers.
  • 6.
  • Where local rules prohibit the
    undertaking of pole line work from a ladder.
    UETTDRRF02B is not mandatory.
  • 7.
  • Not applicable to Cable Jointers who are
    not authorised for live work and are
    restricted to jointing and terminating
    assets that have not been
    commissioned, placed into service or can
    be made live by normal operating
    means.
  • 8.
  • These workers may need to comply with
    UETTDRRF01B when working for an ASP.



www.iacsafetyservices.com.au
or phone 1300 887 317.

HLTAID001
Provide Cardio Pulmonary Resuscitation
UETTDREL14A
Working safely near live electrical apparatus as a non electrical worker
UETTDRRF01B
Apply ESI safety rules, codes of practice and procedures for work on or near electrical apparatus
UETTDRRF02B
Perform pole top rescue
✔* ✔* ✔*
UETTDRRF03B
Perform EWP rescue
✔* ✔* ✔*
UETTDRRF04B
Perform tower rescue
UETTDRRF05B
Perform rescue from switchyard structure at heights
✔*
UETTDRRF06B
Perform rescue from a live LV panel
UETTDRRF07B
Perform cable/pit/trench/excavation rescue
+ + +
UETTDRRF08B
Perform EWP controlled descent escape
✔* ✔* ✔*
UETTDRRF09B
Apply access procedures to work on or near electrical network infrastructure
UETTDRRF10B
Provide first aid in an ESI enviroment
(Every 3 years)
UETTDRRF11A
Testing of connections to low voltage electricity networks

Important: Statutory Training is not included in the specific Category Accreditation training and must be undertaken separately.
This is due to the fact, that many students will have already undertaken these studies especially if they are current ASPs upgrading their accreditations; each student will have different requirements associated with their accreditation; finally and perhaps more importantly, the ASP initial training and assessment study schedule is intensive and time restrictions and workloads simply would not allow for this training to happen in the time frames allocated.

DURATION AND PRICES

ELECTRICIAN PATHWAY

Unit of Competency UEENEEK142A UETTDREL16A UETTDRIS67A Price Duration
UETTDRIS60A (Category IV) $3,500 Week 1
UETTDRIS56A (Category III) $2,500 Week 2
UETTDRIS55A (Category II) $2,000 Week 2
The common pathway includes recognition of electrotechnology with
typically outstanding units to be achieved
Category IV
(Metering)
+ Category III
(Overhead)
+ Category II
(Underground)
$7,500 (Save $500)
Category IV
(Metering)
+ Category III
(Overhead)
$6,000
Category IV
(Metering)
+ Category II
(Underground)
$5,500
The Units above are those which typically are outstanding (not already achieved under
G105 recognition), from both the common and Electrotechnology Electrical pathways.

APPLY to study Student Guide

How to get started
We will conduct recruitment for placements in an ethical and responsible manner. An offer for placement will be based upon an assessment of how your current qualifications, competence and ambitions match the opportunity offered in the qualification/Unit of Competency.

Application > Approved /Enrolled > Induction

To apply, go to www.iacsafetyservices.com.au, select your course of study, and follow the prompts. We will verify that we have received your application. However, this does not mean that it has been approved. In the application process, it is your responsibility to:

• Establish the application closing date.

• Check that you meet the requirements and address the selection criteria specified.

• Where requested, provide copies of your evidence, the originals of which must be verified by IAC Safety Services® or by a Justice of the Peace with an authorisation number; or a barrister, solicitor or attorney; or a Police Officer the rank of Sergeant or above. In any case the following statement must by made by the verifier:

‘I verify this to be a true copy of the document shown to me as the original’

The copy must have the verifier’s Name, Signature, Contact Details, the date and the Official Stamp or Seal of the verifier’s organisation on the copy, if such a stamp exists.

• Keep a copy of your completed form.

Notes:
1. IAC Safety Services® reserves the right to sight original documentation.
2. IAC Safety Services® is not responsible for obtaining information that you have not provided. Such information cannot be verified or considered.
3. Do not send original(s) documents as all documents are destroyed and therefore cannot be returned.
This qualification/Unit of Competency may not be available to International Students.
In the approval / enrolment process, if successful IAC Safety Services® will make you an offer informing you of the commencement date of your study or we will inform you that your application was not successful. Upon enrolment you are entitled to receive all of your learning materials; attend Class; have your competency(s) assessed; and receive eligible ‘Certificates’ or ‘Statements of Attainment’.
Placement is available until the class is full or accepted continuously through the year.
An induction and orientation program will be held on the first day of the course.

THE next step

Apply to study

For further assistance, feel free to talk to one of our friendly staff on
1300 887 317 or email registrar@iacsafetyservices.com.au

Version 2, October 2016